PRO Series Datasheet
Datasheet · R14 · English · PDF 0.5 MB
PRO2000M - View 1Loading 3D model…
Drag to rotateDrag to rotate with one finger. Use the arrow keys to rotate when the model is focused.
Marine inverter/charger
A 2000 W pure sine wave inverter/charger with NMEA 2000 integration for marine electrical systems.
Models in this series
| Nominal DC input | 12 VDC |
|---|---|
| DC operating range | LBCO setting to 18.0 VDC |
| Continuous output at 40°C | 2000 W (resistive load); output derates above 40°C |
| Surge output / duration | 4000 W / 5 s |
| AC output voltage | 120 / 110 / 108 VAC; power reduced to 85% at 110 or 108 VAC |
| Continuous AC current at 120 VAC | 16.7 A |
| Output waveform | Pure sine wave |
| Selectable frequency | 60 / 50 Hz |
| DC current at full load | 192 A |
| Peak / full-load efficiency | 91% / ≥86% |
| Transfer relay rating | 30 A |
| Continuous pass-through current | 24 A |
| AC undervoltage setting | 85-110 VAC; default 90 V |
| Transfer modes | Appliance / UPS |
| Line-to-battery transfer setting | APL: 20 ms / UPS: 10 ms; do not connect motor loads in UPS mode |
| Inverter-to-shore transfer time | <20 ms; 20 s delay |
| Nominal battery voltage | 12 VDC |
| Maximum charge current at 14.4 V | 100 A; derates above 14.4 V and may be reduced by ambient temperature |
| Adjustable charge current | 5-100 A; 5 A steps |
| Custom absorption voltage | 12.0-18.0 V; 0.1 V steps |
| Custom float voltage | 12.0-18.0 V; 0.1 V steps |
| Minimum battery voltage for charging | 0 VDC; lithium-ion requires a certified/listed BMS and manufacturer-specified Custom settings |
| AC input range during charging | 85-140 VAC |
| AC charging input frequency | 50 / 60 Hz |
| Maximum AC charging input current | 24 Arms |
| Power factor at full charge | >0.98 |
| Battery profiles | Flooded, AGM, Gel and Custom; lithium-ion requires a certified/listed BMS and manufacturer-specified Custom settings |
| Charge management | Three-stage charging: Bulk, Absorption, Float. Power Share prioritizes AC loads by reducing charge current. |
| Temperature compensation | Optional compatible battery temperature sensor (BTS). |
| Equalization | Flooded batteries only, when permitted by the battery manufacturer. |
| Protective shutdown | Low battery, overload, short circuit and over-temperature; recovery depends on settings. |
| Network interface | NMEA 2000 |
| Remote control | Optional compatible remote panel through the RJ12 Remote port. |
| GFCI configuration | Customer-provided compatible GFCI protection. |
| Operating ambient temperature | -20 to +60°C; output derates above +40°C; battery manufacturer's temperature limits also apply |
| Storage temperature | -40 to +70°C |
| Operating / storage humidity | 5-95% RH, non-condensing |
| Cooling | Fan controlled by internal temperature or AC output power |
| Net weight | 7.4 kg |
| Overall L × W × H, including flanges | 415.3 × 305.2 × 125.4 mm |
| Outer carton dimensions (L × W × H) | 473 × 388 × 216 mm |
Datasheet · R14 · English · PDF 0.5 MB