DC-DC charger

MDC1250

A 50 A DC-DC charger with alternator and solar inputs, built-in MPPT control and adjustable battery charging.

Maximum charging current
50 A
Nominal output voltage
12 VDC
Communication
CAN / RV-C

Models in this series

  • Automatic alternator and solar input selection
  • 12 V house-battery charging from 12 V or 24 V starter systems
  • Built-in MPPT solar charging control
  • CAN / RV-C communication

Technical specifications

MDC1250 specifications
Maximum charging current50 A
Maximum output power775 W
Nominal output voltage12 VDC
Minimum operating battery voltage8.0 VDC
Selectable charging current5–50 A (5 A steps)
Alternator input (12 V)10.5–16.0 VDC
Alternator input (24 V)21–32 VDC
Input system selection12 / 24 V Auto
Solar input voltage14.5–50 VDC
Maximum solar input current30 A
Solar input power / 24 V panels750 W (800 W max.)
Solar input power / 12 V panels500 W (600 W max.)
Efficiency95%
House-battery draw (ON)<70 mA
House-battery draw (OFF)<0.2 mA
CommunicationCAN / RV-C
Battery profilesGEL / AGM / Flooded / Lithium / Program
GEL bulk / float voltage14.4 / 13.7 VDC
AGM bulk / float voltage14.6 / 13.6 VDC
Flooded bulk / float voltage14.4 / 13.3 VDC
Lithium charging voltage13.9–14.6 VDC
Program charging voltage13.8–14.8 VDC
Operating temperature−20 to 60°C
Storage temperature−40 to 70°C
Relative humidity (non-condensing)5–95% RH
Overall dimensions (L × W × H)223.0 × 170.0 × 81.5 mm
Net weight2.06 kg
Ingress protectionIP32
Maximum alternator input current50 A
Restart voltage (GEL / AGM / Flooded / Program)12.5 VDC
Restart voltage (Lithium)13.3 VDC
Equalization voltage (flooded batteries only)15.5 VDC
Equalization charging current10% of bulk current setting
Charging control (GEL / AGM / Flooded / Program)Two or three stages
Charging control (Lithium)Three stages only
DC output bankSingle
Battery temperature settingLow / Normal / High; overridden by optional BTS

MDC1230 / MDC1250 Datasheet

Datasheet · R2 · English · PDF 0.6 MB

View PDF